Industrial Grade, DC/DC Converter, 40 W

General Characteristics

  • Additional functions : on/off, input current ripple reduction, adjustable undervoltage lockout
  • External synchronization range : no synchro
  • Nominal power up to : 40 W
  • Protections : input undervoltage lockout, output overvoltage, output current
  • Switching frequency : 270 KHz
  • Trim adjustment : 80 to 110 %
  • RoHs

Key Features

  • Flexible isolated dual outputs
  • No load to full load operation
  • Reinforced isolation 3 KVrms
  • Soft start
  • Ultra wide input range 12-160 Vdc

Series Description
The MGRI-40-R series features a range of high density board mounted isolated dc/dc converters. With a 12:1 ultra-wide input voltage range and reinforced isolation (4252V dc test) the MGRI-40-R delivers a double 20W output channel. 
Available in 2x 5, 2x12, or 2x15 volts outputs, each model features a trim function to adjust the output voltages in a 80/110% range. The converter embeds several functions as soft start, and output overload protection. The converter comes in a low profile fully potted metallic case.
 
Read more ...
Product Selection

This product selection table includes all available versions. Other references may be offered – see technical datasheets.
For more information, please consult factory.

Reset filters
Characteristics
More characteristics ...
Reference Status Output power Input voltage Max. transient input voltage Switching frequency Output voltage Output current Min. transient input voltage Output Nbr Max power per channel Case dimensions Standard electrical functions Operating case temp. range Case material Max power in drop out operation UVLO range Output voltage trim Isolation voltage Synchronization freq. range Efficiency Weight Synchronization Options RoHS / SnPb
MGRDI-40-R-C Active 40 W 12-140 Vdc 175.0 Vdc / 100 ms, 160.0 Vdc / 1 s 2 x 5 Vdc 2 x 4 A 10.5 Vdc / 1 s D 45.5 x 38.6 x 10.5 mm UVLO, OCP, OVP, VIF, TRIM
UVLOadj
-40 to 105 °C Metallic black anodized coating 80 to 110 % 3000 Vac Reinforced 87 % 43 Grams N
MGRDI-40-R-E Active 40 W 12-140 Vdc 175.0 Vdc / 100 ms, 160.0 Vdc / 1 s 2 x 12 Vdc 2 x 1.7 A 10.5 Vdc / 1 s D 45.5 x 38.6 x 10.5 mm UVLO, OCP, OVP, VIF, TRIM
UVLOadj
-40 to 105 °C Metallic black anodized coating 80 to 110 % 3000 Vac Reinforced 87 % 43 Grams N
MGRDI-40-R-F Active 40 W 12-140 Vdc 175.0 Vdc / 100 ms, 160.0 Vdc / 1 s 2 x 15 Vdc 2 x 1.35 A 10.5 Vdc / 1 s D 45.5 x 38.6 x 10.5 mm UVLO, OCP, OVP, VIF, TRIM
UVLOadj
-40 to 105 °C Metallic black anodized coating 80 to 110 % 3000 Vac Reinforced 87 % 43 Grams N

Output Nbr: S: Single output, B: Bi-outputs, D: Dual outputs, T: Triple outputs – Dual outputs products can be usable for single output or bi-outputs. Output Nbr E corresponds to a slave module (see DataSheet)
Case dimensions: L x W x H (maximum values in mm)
Standard electrical functions: Case: Case connection, OVLO: Input overvoltage lockout, UVLO: Input under voltage lockout, OCP: Output over current protection level, OPP: Output over power protection, OVP: Output over voltage protection level, SCP: Output short circuit protection, OTP: Over temperature protection, VIF: Pin for Input Current Ripple Reduction, SYNC: Pin for Synchronisation, TRIM: Pin for adjust ouput voltage, ITRIM: Pin for adjustement ouput current limitation, CC: Pin for capacitor charged signal, CD: Pin for capacitor discharged signal, UVLOadj: Pin for level undervoltage lockout adjust, VREF: Pin for output internal voltage reference, PF: Pin for power fail signal, SENSE: Pin for voltage regulation, REV.POL: Reverse polarity protection, SHARE: Pin for output current parallel sharing
Status NPR: Not preferred for new Design
Options: T Screening at start-up -55° C, Y High isolation 3000 Vdc, M On/Off function, S Screening and serialization, F Synchronization function, P Share function

Technical Documentation
Pin Out
Materials Disclosure Disclaimer
Even though all possible efforts have been made to provide you with the most accurate information, we can not guarantee to its completeness and accuracy due to the fact that the data has been compiled based on the ranges provided and some information that may not have been provided by the subcontractors and raw material suppliers to protect their business proprietary information.